FAN-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32, Unsigned32 FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF TEXTUAL-CONVENTION FROM SNMPv2-TC hpSwitch FROM HP-ICF-OID; hpicfFanMIB MODULE-IDENTITY LAST-UPDATED "200808271030Z" --August 27, 2008 10:30 GMT ORGANIZATION "Hewitt-Packard" CONTACT-INFO "k-p-rama.murthy@hp.com" DESCRIPTION "The MIB module is for representing switch fan entity." REVISION "200808271030Z" --August 27, 2008 10:30 GMT DESCRIPTION "Revision 01." ::= { hpSwitch 54 } -- ******************************************************************** -- FAN Textual Conventions -- ******************************************************************** HpicfDcFanIndex ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "A unique value that serves as an index to identify the fan." SYNTAX Unsigned32 HpicfDcFanType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An enumerated value that indications the fan types." SYNTAX INTEGER { unknown(0), mm(1), fm(2), im(3), ps(4), rollup(5), maxtype(6) } HpicfDcFanAirflowDirection ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An enumerated value which provides an indication of the fan airflow direction. The Physical fan airflow direction could be either from the port towards the power supply module i.e. portToPower(1), or from the power supply module towards the port i.e. powerToPort(2)" SYNTAX INTEGER { portToPower(1), powerToPort(2) } HpicfDcFanState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An enumerated value which provides an indication of the fan state." SYNTAX INTEGER { failed(0), removed(1), off(2), underspeed(3), overspeed(4), ok(5), maxstate(6) } -- ******************************************************************** -- Fan Scalars -- ******************************************************************** hpicfFanScalars OBJECT IDENTIFIER ::= { hpicfFanMIB 1 } hpicfFanUserPrefAirflowDir OBJECT-TYPE SYNTAX INTEGER { portToPower(1), powerToPort(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The user preferred fan airflow direction. The direction could be powerToPort or portToPower. The actual fan direction has to be changed manually, this will be used to indicate to the user when when the actual fan airflow direction is different from the user preferred airflow direction." DEFVAL { powerToPort } ::= { hpicfFanScalars 1 } -- ******************************************************************** -- FAN entry -- ******************************************************************** hpicfEntityFan OBJECT IDENTIFIER ::= { hpicfFanMIB 2 } hpicfFanTable OBJECT-TYPE SYNTAX SEQUENCE OF HpicfFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row for every fan in the switch entity." ::= { hpicfEntityFan 1 } hpicfFanEntry OBJECT-TYPE SYNTAX HpicfFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about fan entity table." INDEX { hpicfFanIndex } ::= { hpicfFanTable 1 } HpicfFanEntry ::= SEQUENCE { hpicfFanIndex HpicfDcFanIndex, hpicfFanTray Integer32, hpicfFanType HpicfDcFanType, hpicfFanState HpicfDcFanState, hpicfFanRecovering Integer32, hpicfFanNumFailures Counter32, hpicfFanAirflowDirection HpicfDcFanAirflowDirection } hpicfFanIndex OBJECT-TYPE SYNTAX HpicfDcFanIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index that is used to access the switch fan entry table." ::= { hpicfFanEntry 1 } hpicfFanTray OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The tray number in which the fan is docked." ::= { hpicfFanEntry 2 } hpicfFanType OBJECT-TYPE SYNTAX HpicfDcFanType MAX-ACCESS read-only STATUS current DESCRIPTION "An indication of the vendor-specific fan." ::= { hpicfFanEntry 3 } hpicfFanState OBJECT-TYPE SYNTAX HpicfDcFanState MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the fan." ::= { hpicfFanEntry 4 } hpicfFanRecovering OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An indication that the switch fan entity is faulty. Before declaring a fan to be good after a failure is detected, the same good indication must happen five (5) times in a row. A failure indication is always TRUE, while a good indication could be FALSE, hence this parameter is used to count the repeated good indications before declaring the fan to be good " ::= { hpicfFanEntry 5 } hpicfFanNumFailures OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the fan has failed." ::= { hpicfFanEntry 6 } hpicfFanAirflowDirection OBJECT-TYPE SYNTAX HpicfDcFanAirflowDirection MAX-ACCESS read-only STATUS current DESCRIPTION "Indication of the fan air flow direction, either from Power supply towards the port or from the port towards the power supply." ::= { hpicfFanEntry 7 } -- ******************************************************************** -- FAN Conformance --******************************************************************** hpicfFanConformance OBJECT IDENTIFIER ::= { hpicfFanMIB 3 } hpicfFanCompliance OBJECT IDENTIFIER ::= { hpicfFanConformance 1 } hpicfFanGroups OBJECT IDENTIFIER ::= { hpicfFanConformance 2 } -- ******************************************************************** -- FAN Complicance -- ******************************************************************** hpicfDcFanCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for entries which implement the FAN MIB." MODULE -- This module MANDATORY-GROUPS { hpicfFanScalarsGroup, hpicfFanGroup } GROUP hpicfFanGroup DESCRIPTION "Objects associated with switch entity FAN." ::= { hpicfFanCompliance 1 } -- -- FAN Groups -- hpicfFanScalarsGroup OBJECT-GROUP OBJECTS { hpicfFanUserPrefAirflowDir } STATUS current DESCRIPTION "Basic Scalars required in FAN MIB implementation." ::= { hpicfFanGroups 1 } hpicfFanGroup OBJECT-GROUP OBJECTS { hpicfFanTray, hpicfFanType, hpicfFanState, hpicfFanRecovering, hpicfFanNumFailures, hpicfFanAirflowDirection } STATUS current DESCRIPTION "FAN MIB parameters " ::= { hpicfFanGroups 2 } END